Difference between revisions of "User:Vortex1942/Automating the TEG"
Jump to navigation
Jump to search
Vortex1942 (talk | contribs) (→Pumps) |
Vortex1942 (talk | contribs) |
||
Line 1: | Line 1: | ||
{{Wip | {{Wip|Reason=}} | ||
|Reason= | |||
}} | |||
== Wireless Devices == | |||
== | === Frequencies === | ||
Using a multitool on a WiFi capable device will tell you it's frequency | |||
* Engineering: 122.5 | |||
* Science: 122.9 | |||
* Security: 127.4 :) | |||
{|class="wikitable mw-collapsible mw-collapsed plainrowheaders" style="width: 30%; | |||
|'''Pumps''' | |||
|- | |||
| | |||
=== Pumps === | === Pumps === | ||
Powered down pumps do not transfer gas, Meaning they can be used as controllable Electronic Valves, | Powered down pumps do not transfer gas, Meaning they can be used as controllable Electronic Valves, | ||
==== Commands ==== | ==== Commands ==== | ||
The following points demon | The following points demon | ||
Line 43: | Line 45: | ||
* <code>address_tag</code>: <code>pumpcontrol</code> | * <code>address_tag</code>: <code>pumpcontrol</code> | ||
==== Packet Examples ==== | |||
Purge Hotloop: | Purge Hotloop: | ||
* <code>tag=Hot Loop Purge Pump;command=power_on</code> | * <code>tag=Hot Loop Purge Pump;command=power_on</code> | ||
Line 55: | Line 54: | ||
Set Pressure: | Set Pressure: | ||
* <code>tag=Hot Loop Purge Pump;command=set_target_pressure;parameter=5000</code> | * <code>tag=Hot Loop Purge Pump;command=set_target_pressure;parameter=5000</code> | ||
|} | |||
{|class="wikitable mw-collapsible mw-collapsed plainrowheaders" style="width: 30%; | |||
|'''Gas Mixers''' | |||
|- | |||
| | |||
=== Gas Mixers === | |||
Did I hear you say "Adjustable combustion chamber temperatures?" | |||
==== Commands ==== | |||
* Toggle Power | |||
** <code>command</code>: <code>toggle_pump</code> | |||
** <code>parameter</code>: <code>power_on</code> or <code>power_off</code> | |||
** <code>tag</code>: <code>(Mixer Name)</code> | |||
* Set gas ratio | |||
** '''NOTE''': <code>parameter</code> value is Input 1 ratio only ie. 66 = 66:33 | |||
** <code>command</code>: <code>set_ratio</code> | |||
** <code>parameter</code>: <code>(0-100 Number)</code> | |||
** <code>tag</code>: <code>(Mixer Name)</code> | |||
* Set gas pressure | |||
** '''NOTE''': <code>parameter</code> is an uncapped value | |||
** <code>command</code>: <code>set_ratio</code> | |||
** <code>parameter</code>: <code>(Target Air Pressure)</code> | |||
** <code>tag</code>: <code>(Mixer Name)</code> | |||
==== Packet Examples ==== | |||
* <code>tag= | Set Ratio to 66:33: | ||
* <code>tag=engine_combust_control; command=set_ratio; parameter=66</code> | |||
Set Pressure to 75kPa: | |||
* <code>tag=engine_combust_control; command=set_pressure; parameter=75</code> | |||
Turn off mixer: | |||
* <code>tag=engine_combust_control; command=toggle_pump; parameter=power_off</code> | |||
|} | |||
<code>tag</code>: <code>(Pump Name)</code> | <code>tag</code>: <code>(Pump Name)</code> | ||
<code></code>: <code></code> | <code></code>: <code></code> |
Revision as of 12:52, 13 December 2023
This page is under construction. The following information may be incomplete. |
Wireless Devices
Frequencies
Using a multitool on a WiFi capable device will tell you it's frequency
- Engineering: 122.5
- Science: 122.9
- Security: 127.4 :)
Pumps |
PumpsPowered down pumps do not transfer gas, Meaning they can be used as controllable Electronic Valves, CommandsThe following points demon
Pump StatusThe following is transmited whenever a pump recieves are command
Packet ExamplesPurge Hotloop:
Check All Pumps:
Set Pressure:
|
Gas Mixers |
Gas MixersDid I hear you say "Adjustable combustion chamber temperatures?" Commands
Packet ExamplesSet Ratio to 66:33:
Set Pressure to 75kPa:
Turn off mixer:
|
tag
: (Pump Name)
: